Hi Ahmad, Here are my ...
Hi Ahmad,
Here are my comments
| CALCULATIONS: | |||||||||
| Site Parameters | |||||||||
| Qmax | Qavg | BODin | BODout | ||||||
| m3/d | m3/d | mg/L | mg/L | ||||||
| 14400 | 5000 | 240 | 20 | ||||||
| Design assumptions taken | |||||||||
| f/m | MLVSS | Y | Qufl/Qavg | Qwaste/Qufl | |||||
| 1/d | mg/L | MLVSS/BOD | 2ry clrf ratio of flows | ||||||
| 0.3 | 3000 | 0.5 | 0.26 | 0.03 | |||||
| Calculated Parameters | |||||||||
| V | HRT | Qufl | Qwaste | MLVSS ufl | SRT for V | ||||
| m3 | d | m3/d | m3/d | mg/L | d | ||||
| 1333 | 0.3 | 1300 | 39 | 11538 | 7.28 | 6.67 | |||
| On wasted MLVSS | On cells generation | ||||||||
| COMMENTS: | |||||||||
| 1.- | In above calc, additional volume (2xV) is not "active", is equalization volume | ||||||||
| 2.- | When assuming additional 2xV is with MLVSS, many things may happen: anaerobic decay first | ||||||||
| 3.- | IF 2xV is aeration provided (i.e. DO or respirometry) sludge aging may occur | ||||||||
| 4.- | If Q increses significantly over design outflows and wasting at 2ry Clrifier would go wild | ||||||||
| 5.- | In above conditions on 4. the plant will not comply | ||||||||