Dear Ahmad, I suppose, in ...
Published by Orlando D. Gutiérrez Coronado
Dear Ahmad,
I suppose, in this case, it is not recommendable design the system without an equalization tank. The equalization tank is used to reduce the size of the system and/or to have an easier operation of the system.
Liang have gived to you a very good suggestion.
On the other hand if you want have a numerical solution of this design I try with 19 days in SRT.
Regards,
Orlando D. Gutiérrez Coronado
I suppose, in this case, it is not recommendable design the system without an equalization tank. The equalization tank is used to reduce the size of the system and/or to have an easier operation of the system.
Liang have gived to you a very good suggestion.
On the other hand if you want have a numerical solution of this design I try with 19 days in SRT.
Regards,
Orlando D. Gutiérrez Coronado