I would suggest carrying out ...

Published by

I would suggest carrying out jar tests looking at different coagulants, as it could be an alternative one could be better. But also use jar tests to establish the ideal pH and coagulant dosage. Jar tests could be carried out in combination with zeta potential measurements. 