hello Hasher we can use BDD ...
Published by Gerald Busca, Quazar Consulting Limited
hello Hasher we can use BDD quite effectively
what volume/ flow are you looking at
we can offer direct oxidation or use other technic like adoption destruction on AC we will certainly be lower then 30mg/l.
You can contact me directly gerald.busca@quazarconsulting.co.uk
2 Comments
Hi Asher, if you give me your starting COD levels we can give you an idea of size and costs our technology would be. either as a pre-treatment or to polish your final effluent down to 30ppm. we offer BDD and BDD + adsorption.
gerald
Published by Gerald Busca, Quazar Consulting Limited
Gerald my flows are in the range of 200-300 gpm (average to peak)
Published by Asher Benedict, Senior Staff Engineer
2 Comments
Asher Also if you have an idea of the conductivity of the effluent that would help
Published by Gerald Busca, Quazar Consulting Limited
OK Asher that was in your question 300gpm ~60m3/hr and what is the starting COD? We can do a quick calculation for you. It would definitely be possible to achieve the levels you are looking at but we need to assess if it is viable. Just give me your starting COD for now and we can carry on the conversation. Regards
Published by Gerald Busca, Quazar Consulting Limited