UASB or any anaerobic ...

Published by

UASB or any anaerobic treatment is most economical and best solution for the reduction of COD level. Higher the COD better the results. a reduction of 60-70 is guaranteed and in certain cases, it reaches up to 90% also in single stage UASB. A second stage activated sludge process will bring it within limits for RO feed.  Treatment scheme  UASB>ASP> Tube Settler> MGF> ACF>UF>RO