My experiences to treat black ...
Published by M. Musyafa Wiryanto, Business Development Dir. at PT. Pancawala Indochemical
My experiences to treat black licquor with Up flow Anaerobic Sludge Hankering continued with Up flow Anaerobic Fixed Mediia. Control pH 5.5-6.5 in range to produce Methane gas. The efluent from this system will remove 95-98% of COD. So the affluent will about in 950-1500 ppm in easy for aerobic activated sludge in the next processing.