Published by Abdul Shaikh, International Textile Limited - Manager ETP (Effluent Treatment Plant)
Dear Anvar Mansuri
I don't know about your injection water for waterflooding operations. Water flooding certainly needs the pressure to flooding the water
and also the hole size of the flooding ends. when you are using the seawater which may have TDS between 30,000 to 50,000 mg/l
This means the seawater has the tendency to make the scaling and have to use anti-scaling and also keep your pH between 7 to 8
This could be the chemical treatment. Regarding the filtration, if it is recommended by the manufacturer about SDI 15 which is quite high, Normally when we are using RO we only need max. 3 SDI, You can use the bag filtration as well as cartridge filter with maximum of 2 Micron filter cartridge. Try it and let me know the result.
Also, tell me in detail the problem you are having right now?