Hello Megan, The main risk ...

Published by

Hello Megan,

The main risk concerning the process you choose is clogging, due to biofilms and/or unsufficient SS settling in the septic tank (decantation of hair is fairly difficult).

Did you consider designing a vertical flow constructed wetland, directly fed with raw water?

It requires a higher water head than HFCW, but SS are trapped on the surface of the filter and mineralize rapidly. Together with alternate feeding of 2-3 subfilters, this totally prevents clogging.

Depending on the organic load and outlet spec, total surface area could be between 50 and 90 m², in 1 or 2 stage VFCW.

Good luck for your project!

François (France)