Ensure your pre-treatment ...
Published by Ian Pearson
Ensure your pre-treatment processes produce a final water with a low Silt Density Index - don't only rely on the membrane filter, which is a final polishing step.
The filter needs replacement when the pressure drop reaches the limit permitted for the filter (unless you can wash it separately and replace it for another service - just ensure it is not damaged by the washing process)