Lamella tubes and plates can ...
Published by Zubair Shaikh, Waste Water Treatment and Recycling Projects
Lamella tubes and plates can only be used as a supporting agent in case of troubleshooting like shock load.. However I found that many vendors use the surface area of lamella plates in the calclulation of Surface Overflow rate (SOR), which is the key design parameter in Secondary clarifier design.