@Patrice GR Doherty-Bigara, do not underestimate the work required for a MBR model that includes the effect of the membrane system. If all you want is the process biochemistry you can implement that quickly; but adding the interactions with the membranes is rather more involved.
Because of the need for accuracy you may find it difficult using an Excel spreadsheet without the addition of macros to provide support for solving the differential equations; the standard Excel spreadsheet makes an Euler solver the natural approach, and this is at best inefficient, at worst unstable, for solving the equations associated with activated sludge systems.
Published by jeremy dudley, Senior engineer at WRc plc
RE: irrigation-reuse - cannot buy software for a now and then check/cal's etc! I would like to check your Academic one ! Email is pgrdohertyb@outlook.com
Published by Patrice GR Doherty-Bigara, Senior Mechanical Engineer
Better really to write your own, excel or mathcad files !! we can see what have been assume, used etc.. a template that can be change, modify etc.. RE: for irrigation-reuse!
Published by Patrice GR Doherty-Bigara, Senior Mechanical Engineer