A description of your ...

Published by

A description of your process, parameters and industry would help.

1 Comment

1.the ​stripped sour ​water is ​treated by ​DAF,sludge(combines moving bed ​biofilm and ​activated ​sludge ), filter ​by MBR system, and supply to ​cooling tower ​as part of make-​up water. ​
2.the ​recirculation ​flow of the ​mixed liquor is ​about 3.5Q, to ​meet the MLSS 2,​500~3,500 ppm.the DO is 3~4 ppm; pH 6.5~7.5.
3.the ​influent ​COD 500~800 ppm, NH3-N 2~40 ppm,TKN 15~80 ppm, NO2-N and NO3-N ~0 ppm.
4.the effluent COD 15~40 ppm, NH3-N 10~50 ppm,TKN 15~50 ppm, NO2-N and NO3-N ~0 ppm.