Dear Aquablu, Ther are ...
Published by Orlando D. Gutiérrez Coronado
Dear Aquablu,
Ther are many ways to remove the ntrates, but it will be good have a complete analysis and commments about the wastewater and previous process.
Please describe the process that generrates this wastewater and post a lab analysis.
Regards,
Orlando D. Gutiérrez Coronado
1 Comment
Hello Orlando ..
the source of water is due to a buffering process carried out to cation exchange Ca++ with K+ in a natural grow Medea.
Ca++ is introduced as Ca(NO3)2 . Pls check the results of the analysis.
Conductivity:4800MicS/cm
COD: 1150
BOD:125
pH5.5-6.5
Chlorides659
Other parameters (Minerals, etc):
Nitrate as No3 : 1100 - 1750 mg/l
Nitrite as No2 : 30 - 60 mg/l
Our objective: To remove NO3- to 30ppm or closer.
Discharge limits to achieve,
COD 400ppm / BOD 250ppm / NO3- 30ppm /
Cl- 600ppm ( as CL ) / Conductivity 2250MicS/cm
Published by Aquablu Lanka, Managing Director at Aquablu lanka Pvt ltd