If I follow correctly you have a pH between 2 and 3, with an influent COD of 50,000 mg/L and Oil & Grease (O&G) concentration of 5,000 mg/L. If this is the case, there are many ways to move forward, so I will layout a possible escenario. 

First - you should reduce the O&G concentration by simply installing an O&G skimmer or a DAF.

Second - I am assuming you have an Activated Sludge System to perform your COD removal. Base on this scheme you should have a Equalization Tank and Primary Clarifier to reduce the COD load acceptable for your Aeration Basin System to manage the load. With this system you can also install a Neutralization System that will allow you to control the pH.

Hope this gives you an idea on how to solve your problem. If you would need further assistance you can contact me directly at: Louis.Viana@LRVINC.Com

Regards,

Dr. Louis R. Viana, PE,Ph.D.