Basically it is the dubious ...
Published by Steve Oxtoby, Process Engineer
Basically it is the dubious decision to exclude chemical solutions that is frustrating a reasonable cost solution. An oxidising agent is needed. Oxygen from air can work but only at a high pH and so is not generally effective. Manganese dioxide material in filter media will act as a catalyst and reduce the pH requirement but is still not massively effective without chlorine.