One word - OXIDIATION
Published by Sean Roop, Industrial and Engineering Consultants, LLC - Senior Water and Process Consultant
1 Comment
Actually two words - BREAKPOINT OXIDATION. But use H2O2 for a clean effluent of H2O, Na+, SO4-. You will be fine. Thanks, Sean
Published by Sean Roop, Industrial and Engineering Consultants, LLC - Senior Water and Process Consultant
2 Comments
Thank you Sean !
Published by Pablo Francisco de la Reta
Use an ORP to keep the charge at 0-20 mA and this is breakpoint area especially if you are going into secondary biological immediately. If so consider the benefits over feeding hydrogen peroxide for O2 in you mixed liquor. Sean
Published by Sean Roop, Industrial and Engineering Consultants, LLC - Senior Water and Process Consultant