Hi Goksel, probably i should´nt post my answer as a comment to Mr. Baboo but directly to you - to clearify some facts:

Gerhard Mangold 14 hours ago

Hi Baboo,

I value your ​answer, as you ​tried to ​explain ​standard water ​disinfection ​treatment. But ​I have to ​remind you ​about the ​original ​question wheter ​there are ​regulations for ​water treatment ​in cooling ​towers. See ​Muhammads reply:​ There are no ​existing ​regulations, ​only recommendations ​and standards ​invented by the ​industry. Due ​to the fact ​that legionella ​pneumophila ​evaporated from ​cooling towers ​caused world ​wide serious ​epidemic ​infections with ​high mortality ​rates, ​officials are ​seeking for ​existing ​regulations or ​regulations in ​similar ​appliacations. ​Currently in ​Germany the ​parliament ​passes a new ​regulation, to ​list all ​cooling towers ​by the land ​registry office ​and to enforce ​regular cooling ​tower water ​quality, ​according to ​standards ​defined by the ​German federal ​environmental ​office. The ​standards will ​be the ​same as ​drinking water ​specs and ​limited to 1000 ​KBE or Germ ​Developing ​Entities per ​1000 ml water. ​The regulation ​also froces all ​responsible ​operators to ​control and ​test the water ​quality on a ​regular base, ​to test the ​water through ​certifies labs ​and to document ​the test ​reports. ​Preventive ​meassurements ​or corrective ​meassurements ​taken so far ​are as you ​mentioned ​chemical ​treatments with ​negtive effects ​on the ​equipment or ​environment. ​All the ​standard ​treatments will ​not erradicate ​the biofilms - ​breeding ground ​for bakteries ​and germs. To ​disinfect ​cooling towers, ​you have to use ​(chorine or ​chlorine dioxid)​ continuously, ​treating ​symptoms, but ​never solve the ​problem. Please ​see my previous ​answer. I have ​listed cooling ​tower ​appliactions ​where we ​installed our ​chemical free ​treatment ​system. It ​works permanent ​and we can ​proof that we ​eliminated all ​biofilm and all ​tests over ​years show ​perfect results ​of the tested ​water. ​

Dont you ​agree that we ​have: ​

1. Regulations ​and standards ​in drinking ​water ​applications ​which can be ​easily ​applied to ​cooling tower ​appliactions ​

2. Due to the ​high risk of ​epedemic ​infections ​there is a ​world wide need ​for water ​quality ​regualtions in ​cooling towers ​systems ​

3. Due to ​futher negative ​impact chemical ​disinfection of ​cooling towers ​should be ​replaced by non ​chemical ​treatment ​processes. ​

I would be ​happy to give ​you further ​information ​uppon request. ​

Best, Dipl. ​Ing. Gerhard ​Mangold ​gerhard0261@gmail.com 