I would seriously question the use of PE in this situation. It has high creep so would need frequent clips or support and as others have said it would not work well if there is surge. Also there would be need for thrust anchors at bends and fittings. I would suggest an iron pipe would be the best solution. I'm a PE fan and have used miles of it but need to question the wisdom here. 