Hi, They offer different ...
Published by Mariam Ganji, Head Of Technical Department at Avijeh Palayesh
Hi,
They offer different active areas ,and it means higher productivity at lower operating fluxes and lower energy consumption (440i>400i>380 active area).It depends directly on the product flow rate and selected flux of the system .more details are mentioned on their data sheet.
also interlocking endcaps(i coded) mainly reduce the risk of leakage from Orings and even less time consuming in loading of pressure vessels this point would be considered on operating and maintenance costs.
1 Comment
Thanks
Published by Ahmadi Arsalan, Water Purification- Reverse Osmosis at Natural Seawater Desalination Ltd