Hi Shawn, First you need ...
Published by Bruno Peeters, managing director at Model Engineering
Hi Shawn,
First you need selfcleaning fine screens or sieves to retain and remove fibers and other large solids which would otherwise result in clogging and damage downstream. Next a gravity trap shall remove the sand/grit upstream of a mixed buffer/equalisation tank where the bleach will decompose in short time (depending on wastewater temperature). UF as proposed by others will only remove solids. As a result all soluble pollutants including smelly volatile compounds would be recycled. Using ozone would be very inefficient and expensive as main treatment to oxidize these soluble pollutants. Instead we use advanced biological treatment as most sustainable and efficient main treatment followed by UF and ozonation as polishing.