Hi Lin, as Philippe has ...

Published by

Hi Lin, as Philippe has said, the DO in the sludge return should be very low and not a problem.  However I am trying to understand your process.  You say the treatment seq

1 Comment

1.The ​wastewater is ​treated by ​Anoxic, Oxic, ​and by ​degassing ​process.The ​wastewater of ​the oxic stage ​do not back to ​the anoxic ​stage now. The ​sludge ​of the ​oxic stage deal ​by the DAF ​​process, and ​​return to the ​​anoxic process ​
2.if the DO ​of the oxic ​stage is 5~8 ​ppm, the ​nitrification ​reaction rate ​is not stabile, ​we think the ​high DO weak ​the active of ​the anoxic ​bacteria in the ​sludge, until ​we lower the DO ​of oxic stage ​to ~3 ppm, and ​the nitrification ​reaction is ​stabile, the ​denitrification ​reaction rate ​will be 40~50%.

Published by

Permalink