Hi Arsalan, I agree with ...
Published by Andries Loubser
Hi Arsalan,
I agree with the other comments. The TDS should be less than the Conductivity. Based on your chemical species you may have added a '0' to your TDS value. Standard conductivity probes only go up to 20 mS/cm. Did you use a specialist probe for the test? For these high salinity applications, the TDS and/or TS (@105dC) would give a more accurate value.
In general RO desal systems can be designed and operated very efficiently for TDS
1 Comment
Yes, I am Sorry,
EC is 117800 uS/cm and TDS is 82400 ppm.
Unfortunately, I do not know how the experiments were done and what equipment they used.
Published by Ahmadi Arsalan, Water Purification- Reverse Osmosis at Natural Seawater Desalination Ltd