Hi    What is the flow ...

Published by

Hi 

 

What is the flow rate , can you please specify 

1. Do you have an activated sludge treatment process in place. 

 

2. Can you share the analysis of the waste water. 

3. What is the temperature of the incoming waste . 

4. what results you are looking for? 

 

Based on your response a proper workable option can be proposed. 

 

 

1 Comment

1.the wastewater flow rate from acrylonitrile process  is 1,300 M3/D

2.the ​volume of activated ​sludge ​treatment ​ is 5,000 M3, but the wastewater contain 1,300 M3/D from acrylonitrile process and 2,700 M3/D from epichlorohydrin process.

3.the COD of inflow is 1,800 ppm, the COD of effluent is 70 ppm, the reduction rate is 96%.

4.the Temp. of acrylonitrile process wastewater could be near 40 oC.

5.we wish the 1,300 M3/D acrylonitrile process wastewater can be dilute and treat in another ​activated ​sludge ​treatment ​process, and this process , MBR system, could be the equipment for wastewater reuse.

Published by

Permalink