Dear Lokesh, Would you ...
Published by Santiago Cotic, Sales Manager at SNF
Dear Lokesh,
Would you mind telling us a little more about your process. Are your filters installed after a clarification systrem, or they are fed by raw water?
If possible do add a raw water analysis and a brief description of the whole plant process.
Kind Regards,
S. Cotic
1 Comment
I suppose this can be the potential reason of Filter clogging.
Actually, because of algae mass pH of raw water (river water) has increased to a large (pH About 8.2-8.4). Coagulant PAC (Poly Aluminium Chloride) does not work efficiently in this pH range. Nor high Chlorination was giving good results.
So, we Applied Alum as Coagulant with high dose.
However, turbidity of water is between 20-26 NTU Low.
Now, it is working well better than before.
Thanks for your comments Sir
Regards