Has the inlet SS ...

Published by

Has the inlet SS concentration changed?

You must open the filter and take a look about the sand. Microbiological developments can foul the sand. In this case you must make a strong backwash with hipoclorite to remove the biofilm.

In some cases the sand acts like a nucleation agent and a mineral scale could be seen.

1 Comment

I suppose ​​this can be the ​​potential ​​reason of ​​Filter clogging.​​

Actually, ​​because of ​​algae mass pH ​​of raw water (​​river water) ​​has increased ​​to a large (pH ​​About 8.2-8.4). ​​Coagulant PAC (​​Poly Aluminium ​​Chloride) does ​​not work ​​efficiently in ​​this pH range. ​​Nor high ​​Chlorination ​​was giving good ​​results. ​ ​

So, we ​​Applied Alum as ​​Coagulant with ​​high dose. ​ ​

However, ​​turbidity of ​​water is ​​between 20-26 ​​NTU Low. ​ ​

Now, it is ​​working well ​​better than ​​before. ​ ​

Thanks for ​​your comments ​​Sir

 

Regards

Published by

Permalink