Naveed, Depending upon your ...

Published by

Naveed,

Depending upon your water analysis and what level of concentration you are starting with and what level of tail end you are trying to achieve.  If this water is coming from a fracking process, I take it the Bromide concentration is in range of 1 to 2 g/l. There are a number of electrocoagulation followed by a membrane or Fe resin or filter technologies you can adopt for removal of Bromate. Would you be able to share the water analysis and what the level of Bromate limit you are trying to achieve?

1 Comment

Sir, 

it is Interesting to used electrocoagulation. our product is Natural Mineral water, kindly share with compatable with this. we ahve 30ppb & limit is >10ppb.

Published by

Permalink

1 Comment