Hi Lara! After determining ...
Published by Gareth Noel Limcaco, Div Head - Water Treatment at Chemical Research Products Industrial Sales Inc.
Hi Lara! After determining the influent characteristics, you have to determine the foorprint for the design. In our case, some places here have small foorprint and would be impossible to employ a full SBR technology. We usually employ MBR. If the waste is combination of domestic and septic, you might want to have an oil separation process then ABR (Anaerobic Baffled Reactor) or Anoxic, then equalization lastly MBR. If high COD, employ a clarification system before the biological process