Simple methodUnits requiring ...

Published by

Simple method

Units requiring the power/energy are as below

  1. Feed water Pump
  2. High pressure Pump
  3. Disinfection unit (UV plant)
  4. Backwash /Chemical cleaning Pump

Find out run hours of each unit in one day operation.

Power can be calculated as below

  1. Pump power HP  
  2. Time run hour

Power in KWH consumed HP of Pump*0.75*run hour

This way one can calculate energy required for each unit. Summation of will give total energy requirement.