Hi Ali, what do you mean with ...
Published by Bernhard Steiner, WAV Process Engineering GmbH - www.wav.co.at
2 Comments
I would recommend to check and adjust the time intervals for backwash and CEB and also the related chemicals for CEB and/or CIP. Do you use also a recommended strainer (150 micrometer) at the UF inlet? It seams that the UF is overloaded!
Published by Bernhard Steiner, WAV Process Engineering GmbH - www.wav.co.at
Thanks,
Yes UF for RO...... But SDI is also in normal range.
only problem UF system is old & due not proper operation UF membrane Block, required whole UF system rehabilitation.
Published by Mohsan Ali Chaudhry