Published by Engr. Mansoor Ahmed PhD. Scholar, Consultant/Advisor Water/Wastewater Treatment - Consultant
One more question, do you pre-treat the water by UF for RO? If that is the case then you cannot avoid UF membranes as SDI will be much higher to clog your RO Membranes if you bypass UF Membranes.
In addition, DOW UF has an exceptional feature which others UF membrane manufactures have, that is Air Scouring, you can increase time of Air Scouring to eliminate the suspended particles accumulation and Air Scouring is also a Scheduled Task while it goes to Backwash after 12 hrs interval.
3 Comments
Thank Dr.
But we want to replace UF with media filtration,
Just let me know if you have Pre Treatment Media Filtration Design specification & Basics,
Published by Mohsan Ali Chaudhry
1 Comment
Yes dear Mosin Ali we can design for you the prefiltration system. Please send me details in all aspects to my email address
mansoorahmed70@gmail.com
Published by Engr. Mansoor Ahmed PhD. Scholar, Consultant/Advisor Water/Wastewater Treatment - Consultant
HI
I agree with Mr.Ahamed,
it is very important which type of raw water you used, if surface water and sea water is raw water used in your system ,the UF pretreatment was suitable choice.
Published by Ali Cheraghi
1 Comment
Borehole Water not Sea Water conductivity 25000us
Published by Mohsan Ali Chaudhry
Thank Dr.
Ans. 01: Yes UF for RO...... But SDI is also in normal range.
02: Yes i agree but only problem UF system is old & due not proper operation UF membrane Block, required whole UF system rehabilitation.
Published by Mohsan Ali Chaudhry
1 Comment
SDI being normal means
Published by Engr. Mansoor Ahmed PhD. Scholar, Consultant/Advisor Water/Wastewater Treatment - Consultant